# Firmware Lifecycle
# Requirements
Note
Before OTA make sure to go through the list below:
- It is recommended to update the device in the IDLE mode without receiving and executing any commands from Modbus, Enapter Cloud, Enapter Mobile App, Web GUI or others.
- Make sure you have physical access to the device before starting the update process.
- Do not power off the device during the firmware update.
- Before Offline update from 3.7.x please check and correct (if it is needed) device’s system time.
- Remove Dryer Control Network before updating the firmware.
- If Site has Enapter Gateway it needs to be updated to version 1.8.9 or higher.
- Dryer connected to DCN/IDCN should be version 3.6.0 or higher, otherwise it won't be possible to connect Electrolysers to IDCN, monitor and control Dryer from Electrolyser Web GUI or Modbus TCP interface.
# Change Log
# New Features
- Improved WX_16 event triggering when electrolyte circulation pump is off.
- New event Fatal Error FX_44:
Hydrogen sensor broken
was introduced. - Web GUI stability has been improved with DCN.
- Improved FX_13 event false positives.
Factory Settings Reset
is required to apply this update. - Added diagnostics for support.
- New event Warning WS_33:
The electrolyser has been inactive for a long time
was introduced to check the age of electrolyte due to absence of startups. - Added possibility to change Stop and Restart Pressure over Cloud Web Interface.
- Added support for new hardware product codes: ELE410535A2ASV04 and ELE410535A2LSV04.
- The Hardware Clock (RTC) is independent from System Time.
# Compatibility Matrix
Please carefully check the compatibility matrix for the 3.8.0 firmware version with the previous version.
Legend:
- C - fully compatible;
- NC - not compatible;
- PC - party compatible, check additional notes.
3.7.1 | |
---|---|
OTA Upgradable | C |
Modbus Communication Backward Compatibility | C |
Configuration | C |
Rollback | C |
# Functional Depreciation Statements
None
# Known Bugs List
The list below contains the most important problems in the firmware and their solutions.
This version of firmware can cause false positive triggering of FS_12 (Insufficient stack current) event when production rate set to 60%.
Solution: Use 65% production rate as a minimum production rate until the patch version of firmware will be released.
It is an issue using WiFi and Windows to access the
.local
hostname.Solution: Use a local ethernet connection to the electrolyser or IP address as a hostname.
DCN may assign an IP address to devices (computers, mobiles) connected to Wi-Fi AP associated with DCN enabled Enapter devices.
Solution:
- Delete the DCN from the Enapter Mobile App and create it one more time.
- If it is possible try to separate the DCN from your main network environment by connecting the DCN to another WiFi AP. It is no need to separate one DCN from another.