# Firmware Lifecycle
# Requirements
Note
Before OTA make sure to go through the list below.
- Make sure you have physical access to the device before starting the update process.
- Do not power off the device during the firmware update.
- If Site has Enapter Gateway it needs to be updated to version 1.8.9 or higher.
- Remove the Dryer Control Network (DCN) before updating the firmware (no need since 3.3.0).
- Electrolysers connected to DCN/IDCN should be version 1.10.0 or higher, otherwise monitoring and control from Electrolyser Web GUI or Modbus TCP interface won't work.
# Change Log
# New Features
- Add sticky button warning, error code - WP_02.
- Add invalid configuration error, error code - FP_01.
- Add serial communication warning to Enapter Cloud and Electrolyser Web GUI, error code - WH_01.
- Allow to add Water Tank (opens new window) into DCN/IDCN.
- Electrolyser Web GUI: add possibility to reboot UCM.
- Electrolyser Web GUI: add possibility to configure PT01 Min/Max.
- Electrolyser Modbus TCP: add holding register #6021 to read current Dryer state.
- Electrolyser Modbus TCP: add holding register #6022 to persist updated values of PT01 min (holding register #6014) and PT01 max (holding register #6016).
- Electrolyser Modbus TCP: add number of times Dryer was rebooted (read holding register #6020).
- Electrolyser Modbus TCP: allow to reboot UCM (write 1 to holding register #6024 to reboot UCM).
- Electrolyser Modbus TCP: allow to locate device (write 1 to holding register #6023 to enable device locating, write 0 to disable device locating).
# Bug Fixes
- Stabilize IDCN creation.
- Fix fan RPM calculation.
- Properly show drying time left (in non-drying states) in Enapter Cloud.
# Compatibility Matrix
Please carefully check the compatibility matrix for the 3.6.0 firmware version with the previous version.
Legend:
- C - fully compatible;
- NC - not compatible;
- PC - party compatible, check additional notes.
3.5.1 | |
---|---|
OTA Upgradable | C |
Rollback | C |
# Functional Depreciation Statements
# Modbus Compatibility
- Begin with firmware version 3.6.0 Dryer input registers are deprecated, holding registers should be used instead.
# Known Bugs List
The list below contains the most important problems in the firmware and their solutions.
DCN may assign an IP address to devices (computers, mobiles) connected to Wi-Fi AP associated with DCN enabled Enapter devices.
Solution:
- Delete the DCN from the Enapter Mobile App and create it one more time.
- If it is possible try to separate the DCN from your main network environment by connecting the DCN to another WiFi AP, no need to separate one DCN from another.
Was this page useful?